Atlas AA200PHD 200W 6 Input Mixer Amplifier with PHD Circuit

ITEM #: AA200PHD MFG #: AA200PHD

Primary Image
  • Product Image Thumbnail 1 of 3
  • Product Image Thumbnail 2 of 3
  • Product Image Thumbnail 3 of 3
Free Shipping with $49 Minimum Order

List Price:

$1,155.99

Our Price:

$926.99

Availability: Ships Factory Direct, Typically in 3-10 Business Days
iAvailability Description Popup


    AA200PHD - Overview

    The Atlas AA200PHD is a six input channel mixer amplifier designed for distributed business paging and background music (BGM) systems, medium to large speech privacy systems, and in applications where music on hold (MOH) plus paging is required.

    With one microphone/line input and two stereo line inputs, the AA200PHD will accommodate a variety of input sources including paging microphones, media players, and digital music receivers. The AA200PHD includes a patent pending automatic system test, the Push Here Diagnostic (PHD). The PHD button is designed to check the connected speaker lines for wiring and impedance errors. This test can be activated once all speakers are connected and the circuit automatically verifies that the attached speakers' tap settings do not exceed the amplifier's rated power, no speakers are mistakenly tapped at 8 Ohm, and the speaker wire is free from shorts. The unit also incorporates a Remote Input Selection and Remote Level Control feature that allows the integrator to use a remote wall plate (Atlas Sound model WPD-RISRL) and allow the user to select the input and adjust the volume from that wall plate up to 200 feet from the amplifier.

    The AA200PHD provides 200-watts output power into 25V, 70.7V, or 4 Ohm speaker systems. Rear panel DIP switch allows for creation of Zone 2 output mix using any or all of inputs 1-4. Unit can also be set-up to mute Inputs 2 through 6 on signal from Input 1 for paging applications where other input sources need to be muted during a page. Inputs 1-4 are either Mic or Line input selectable and Phantom Power is an option when using them as a microphone input.

    • Features:

      • 200W into 25V/70.7V and 4O Loads
      • Automated Diagnostic System Test (Push Here Diagnostic)
      • Four Balanced Mic/Line/Tel Inputs w/ Phantom Power
      • Three Unbalanced, Summing Line Level Inputs
      • Input Assignable Zone 2 Output
      • Remote Level Control
      • Remote Input Select (RIS)
      • Line Output
      • Preamp In for External Processors
      • Variable Mute Sensitivity Control for Input 1
      • Contact Closure Mute Terminals
       
    • Specifications:

      • Type: Mixer Amplifier
      • RoHS Compliant: Yes
      • Safety Listings: ETL (UL 60065 Standard)

        Electical Specifications
      • Power Output Max. Average Power @ 50Hz-15kHz with .5% THD, 4 Ohm 200W RMS
      • Transformer Outputs
      • 25V 200W RMS
      • 70.7V 200W RMS
      • 4 Ohm 200W RMS

        Front Panel
      • Power Switch: Push Type
      • Indicators: Signal, Peak, Limit, Power
      • PHD Test Circuit: Push Momentary
      • Level Controls: Master, Inputs 1 - 6

        Rear Panel
      • Inputs
      • Mic / Line Balanced Qty 4, 3 Position PHX Type. 3.5mm Pitch
      • Auxiliary Unbalanced Qty 2, RCA
      • Auxiliary Unbalanced Qty 1, 3.5mm
      • Amp In: Unbalanced RCA 600 Ohm
      • Tone Controls
      • Bass ±6dB @ 100Hz
      • Treble ±6dB @ 10kHz
      • Mute: VOX Sensitivity: Pot Rotary, Range (-) 500uV +/-200uV
      • Remote Mute: Contact Closure, 2 Position Phoenix, 3.5mm Pitch

        Remote Level
      • Type: 10V DCV Return
      • Connector: 4 Position Phoenix 3.5mm Pitch
      • Control Port: Input 2
      • Control Port: Input 4, 5, 6 or DIP Swicth Assigned Master
      • Supply Port: 10VDC Send
      • Ground Port: Ground

        Remote Input Select
      • Type: Ground Activated
      • Connector: 4 Position Phoenix 3.5mm Pitch
      • Inputs Controlled: 4, 5, 6

        Control Switch Funtctions
      • Zone 2 Assign: Inputs 1, 2, 3, 4
      • Mute Receive: Inputs 1, 2, 3, 4. 5. 6
      • Phantom Power: Inputs 1, 2, 3, 4
      • Mic/Line Select: Inputs 1, 2, 3, 4
      • Remote Level: Assigned Master or Inputs 4, 5, 6
      • RIS: On/Off

        Outputs
      • Main: Transformer Coupled, Balanced, 4 Ohm, 25V, and 70.7V. Class 2 Rated, Removable 4 Position PHX 5.08mm Pitch, Accepts up to 12 - 24 Gauge Wire, 12A Rating
      • Zone 2: Unbalanced 600 Ohm / 10k Ohm, Max 1.0V Out, Removable 2 Position PHX 3.5mm Pitch, Accepts up to 18 - 26 Gauge Wire, 8A Rating
      • Pre Out: RCA, Unbalanced 150 Ohm

        Technical Data
      • Inputs: Total Qty 4
      • Frequency Response: 50Hz - 15kHz +/- 3dB
      • Thd+N: 0.5% or Less, at 1kHz, Rated Output
      • Input Sensitivity / Impedance
      • Input 1, 2, 3, 4 - Mic Mode 5mv, No Trim, 1200 Ohm
      • Input 1, 2, 3, 4 - Line Mode 316mV (-10dBV) 1200 Ohm
      • Input 4 - 3.5mm Summed 3, 4 316mV (-10dBV) 10k Ohm
      • Input 4, 5, 6 - RCA Unbalanced Summed 316mV (-10dBV) 10kOhm
      • Signal To Noise Ratio
      • Mic >55dB
      • Line >55dB
      • Telephone >55dB
      • Input 3/4 >75dB
      • Phantom Power: 24VDC

        Power Requirements
      • AC Mains: 120V 60Hz
      • AC Cord: 2M, 18 Gauge, NEMA 5-20P
      • Idle Power: .07A, 6W, 39 BTU
      • Average Power: .28A, 30W, 101 BTU
      • Max Power: .86A, 89W, 303 BTU

        Mechanical
      • Chassis: Steel
      • Finish: Black Paint on Front and Top
      • Height: 3.66" (93mm)
      • Width: 16.54" (420mm)
      • Depth: 14.6" (422mm)
       
    • GTIN:

      0612079190867
       

    AA200PHD - Required Accessories

      California Residents:
      WARNING:
      Cancer and Reproductive Harm - www.P65Warnings.ca.gov