Tripp Lite SU6000RT4U 6000VA 4200W UPS Smart Online Rackmount 6kVA PDU 208/240/120V 4U

ITEM #: TRL-SU6000RT4U MFG #: SU6000RT4U

Primary Image
  • Product Image Thumbnail 1 of 5
  • Product Image Thumbnail 2 of 5
  • Product Image Thumbnail 3 of 5
  • Product Image Thumbnail 4 of 5
  • Product Image Thumbnail 5 of 5

This item is no longer available.
Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the TRL-SU6000RT4U

SU6000RT4U - Overview

Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the Tripp Lite SU6000RT4U provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems. The SU6000RT4U has a 6kVA/4200W capacity, NEMA L14-30P 4-wire split-phase input and 12 total AC outlets (8 5-15/20R; 2 L6-20R; 2 L6-30R).

With its detachable PDU, the SU6000RT4U is easily hot-swappable by a user of any skill set--no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation.

UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4U's runtime can be expanded with optional external battery packs.

The SU6000RT4U features a highly efficient (94%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.

An LCD display with LED indicators enables IT personnel to monitor operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.

The SU6000RT4U features a USB port and a DB9 port that, when used with Tripp Lite's PowerAlert software, provides comprehensive network power monitoring and control. An optional network accessory card enables the UPS to operate as a network managed device.

The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory.

The SU6000RT4U comes with $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment.

  • Features:

    • Completely user hot-swappable-no service call or technician needed
    • Included maintenance bypass switch enables live replacement of UPS with zero downtime
    • Protects rackmount servers, telecom systems and other networking equipment with true on-line operation, pure sine wave output and zero transfer time to battery
    • 12 AC outlets (8 5-15/20R; 2 L6-20R; 2 L6-30R)
    • 6kVA/4200W capacity in 4U form factor with power module and independent, detachable PDU
    • Hot-swappable power and battery modules
    • 20-minute half-load runtime, 8-minute full-load; expandable runtime with external battery packs
     
  • Specifications:

    • Input
    • Rated input current (Maximum Load): 24A
    • Nominal Input Voltage(s) Supported: 120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G)
    • UPS Input Connection Type: L14-30P
    • UPS Input Connection Description: 4 wire split-phase input (L1, L2, N, G)
    • UPS Input Cord Length (ft.): 10
    • Recommended Electrical Service: 30A 208/120V Split Phase
    • Input Phase: Single-Phase

      Output
    • Output Volt Amp Capacity (VA): 6000
    • Output kVA Capacity (kVA): 6
    • Output Watt Capacity (Watts): 4200
    • Output kW Capacity (kW): 4.2
    • Power Factor: 0.7
    • Crest Factor: 3:1
    • Nominal Voltage Details: 240/120 or 208/120 split phase output
    • Frequency Compatibility: 60 Hz
    • Output Voltage Regulation (Line Mode): +/- 3%
    • Output Voltage Regulation (Economy Line Mode): +/- 10%
    • Output Voltage Regulation (Battery Mode): +/- 3%
    • Output Circuit Breakers: 20A branch rated breakers (x4) protect 2 5-15/20R outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R outlets are unbreakered
    • Output AC Waveform (AC Mode): Pure Sine wave
    • Output AC Waveform (Battery Mode): Pure Sine wave
    • Nominal Output Voltage(s) Supported: 120V; 208V; 240V
    • Output Receptacles: (8) 5-15/20R; (2) L6-20R; (2) L6-30R
    • Individually Controllable Load Banks: No

      Battery
    • Full Load Runtime (min.): 8 min. (4200w)
    • Half Load Runtime (min.): 20 min. (2100w)
    • Expandable Battery Runtime: Supports extended runtime with optional external battery packs
    • External Battery Pack Compatibility: BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH
    • DC System Voltage (VDC): 192
    • Battery Recharge Rate (Included Batteries): Less than 6 hours from 10% to 80% (typical, full load discharge)
    • Internal UPS Replacement Battery Cartridge: RBC9-192

      Voltage Regulation
    • Voltage Regulation Description: +/-3% output voltage regulation in online, double-conversion mode
    • Overvoltage Correction: Corrects overvoltages to 140 (measured L1-N : L2-N)
    • Undervoltage Correction: Corrects undervoltages to 65 (measured L1-N : L2-N)

      Surge / Noise Suppression
    • UPS AC Suppression Joule Rating: 1810
    • UPS AC Suppression Response Time: Instantaneous
    • EMI / RFI AC Noise Suppression: Yes
    • AC Suppression Response Time: Instantaneous

      Physical
    • Cooling Method: Fan
    • Included Mounting Accessory Description: 4 post rackmount installation accessories included
    • Maximum Device Depth (in.): 30.6
    • Minimum Required Rack Depth with External Battery Pack (cm): 87
    • Minimum Required Rack Depth with External Battery Pack (in.): 34.2
    • Minimum Required Rack Depth without External Battery Pack (cm): 87
    • Minimum Required Rack Depth without External Battery Pack (in.): 34.2
    • Primary Form Factor: Rackmount
    • Rack Height: 4U
    • Shipping Dimensions (hwd / in.): 13.25 x 23.50 x 37.00
    • Shipping Weight (lbs.): 222.00

      Environmental
    • Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
    • Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
    • Relative Humidity: 0 to 95%, non-condensing
    • AC Mode BTU / Hr. (Full Load): 1593
    • AC Economy Mode BTU / Hr. (Full Load): 914
    • Battery Mode BTU / Hr. (Full Load): 1419
    • AC Economy Mode Efficiency Rating (100% Load): 94%
    • Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
    • Audible Noise: 60 dBA at front side 1 meter
    • Operating Elevation (m): 0-3000 m

      Communications
    • Network Management Cards: SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD
    • Communications Cable: USB and DB9 cabling included
    • Communications Interface: Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
     
  • GTIN:

    0037332125217
     

SU6000RT4U - Required Accessories

    California Residents:
    WARNING:
    Cancer and Reproductive Harm - www.P65Warnings.ca.gov