Tripp Lite SU16KRT8 16000VA 14400W UPS Smart Online Rackmount 16kVA PDU 200V-240V 12U

ITEM #: TRL-SU16KRT8 MFG #: SU16KRT8

Primary Image
  • Product Image Thumbnail 1 of 5
  • Product Image Thumbnail 2 of 5
  • Product Image Thumbnail 3 of 5
  • Product Image Thumbnail 4 of 5
  • Product Image Thumbnail 5 of 5

This item is no longer available.
Ask a Markertek Expert if you need assistance finding an appropriate substitute.

(800) 522-2025Email

Items similar to the TRL-SU16KRT8

SU16KRT8 - Overview

Tripp Lite SU16KRT8 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.


What does Uninterruptible Power Supply (UPS) mean?
An uninterruptible power supply (UPS) provides nearly instantaneous power when the main utility power source fails, allowing either time for power to return or for the user to shut down the system or equipment normally by closing running computer system applications and using the operating system to shut down the system. The user has between five and 15 minutes to shut down a system normally or bring an auxiliary power source online to restore the power supply. In addition, most UPS systems also work to address power source electrical surges, sag voltage, voltage spikes, frequency instability, noise interference or harmonic distortion from the ideal sinusoidal wave form. If you're concerned about power failures, especially if you've lost work on your computer due to power outages in the past, you should buy a UPS. A UPS combines a surge suppressor with a big battery, and has special circuitry that detects a power failure and quickly switches over to run your equipment on its battery. The sole purpose of a UPS is to give you a few minutes at the start of a power failure to do two things:
-Save your work, and
-Shut down your computer.
Please Note: A UPS is not designed to let you continue to use your computer for hours and hours until the power comes back on. If properly chosen, a UPS will give you 5 to 10 minutes (possibly more) to Save and do an orderly Shutdown.

  • Features:

    • Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENG, FR, GER, IT, SP and POR.
    • Expandable Battery Runtime , Runtime is expandable with external battery packs, External Battery Pack Compatibility BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH.
    • Included Mounting Accessory 4 sets of adjustable 4 post rack rails included (one for each included 3U module), Optional Mounting Accessory, Qty 4 2POSTRMKITHD and Qty 2 2-9USTAND required.
     
  • Specifications:

    • Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
    • Output Volt Amp Capacity (VA) 20000
    • Output kVA Capacity (kVA) 20
    • Output Watt Capacity (Watts) 18000
    • Output kW Capacity (kW) 18
    • Power Factor 0.9
    • Crest Factor 0.125694444444444
    • Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
    • Nominal Voltage Details Voltage selection via front panel LCD interface
    • Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
    • Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
    • Output Voltage Regulation (Line ) +/- 2%
    • Output Voltage Regulation (Economy Line) +/- 10%
    • Output Voltage Regulation (Battery) +/- 2%
    • Output Receptacles Hardwire
    • Output Receptacle Details Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
    • Output AC Waveform (AC) Pure Sine wave
    • Output AC Waveform (Battery) Pure Sine wave
    • Rated input current (Max Load) 112.2A (200V), 108A (208V), 102A (220V), 97.6A (230V), 93.6A (240V)
    • Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
    • UPS Input Connection Type Hardwire
    • UPS Input Connection Description Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
    • Recommended Electrical Service 120A @ 200V-240V (L, N, PE), or 125A @ 200V, 208V, or 240V (L1, L2, G)
    • Input Phase Single-Phase
    • Full Load Runtime 4.3 minutes (18,000 watts)
    • Half Load Runtime 12.5 minutes (9000 watts)
    • Expandable Runtime Description For best results, add external batteries in multiples of two so that both included 10kVA power modules have an equal number and type of connected battery packs
    • DC System Voltage (VDC) 240
    • Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
    • Battery Replacement Description Hot-swappable, user replaceable external battery packs
    • Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode
    • Overvoltage Correction Corrects overvoltages up to 300V
    • Undervoltage Correction Corrects undervoltages as low as 100V
    • Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
    • Alarm Cancel Operation Alarm cancel switch
    • Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
    • LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
    • UPS AC Suppression Response Time Instantaneous
    • EMI / RFI AC Noise Suppression Yes
    • UPS Power Module Dimensions 5.14" x 17.5" x 25.82"
    • Installed Whole System Maximum Rack Depth 32.5"
    • Rack Height 12U
    • UPS Power Module Weight 44.1 lbs
    • UPS Dimensions Details Includes 2 SU1000RT3UPM UPS/Power modules and 2 BP240V10RT3U Battery packs; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit
    • Included Battery Pack Dimensions 5.25" x 17.5" x 25"
    • Included Battery Pack Weight 158.7 lbs
    • UPS Shipping Dimensions 36" x 40.25" x 51"
    • Shipping Weight 600 lbs
     